ABSTRACT

This study aims to analyze to conclude the optimum conditions required for the electro flocculation process and the effect of variations in electric voltage and contact time on decreasing the concentration of fatty oil and COD. The raw material used in this research is wastewater taken from car and motorcycle washing waste. The process is run in batches using a device designed with the principle of electro flocculation with a maximum capacity of 5 liters. The parameters used are the content of Fatty Oil and Chemical Oxygen Demand (COD) with variations in voltage and contact time.

The stages carried out consist of the preparation stage and the main experiment. In the preparation stage, the activities carried out are sampling and preservation. At the experimental stage, the main activities carried out are determining the optimum stress and determining the optimum contact time. The voltage variation used when determining the optimum voltage is 4.5v; 6v; 7v; 9v and 12v. Variations of contact time used when determining the optimum contact time were 15 minutes, 30 minutes, 45 minutes, 60 minutes, and 75 minutes.

In an experiment to determine the optimum conditions required for the electro flocculation process, it was found that the changes given to the voltage and contact time greatly affected changes in fatty oils and COD.

INTISARI

Penelitian ini bertujuan untuk menganalisa hingga menyimpulkan kondisi optimum yang diperlukan bagi proses elektroflokulasi dan pengaruh variasi tegangan listrik dan waktu kontak terhadap penurunan konsentrasi Minyak lemak dan COD. Bahan baku yang digunakan dalam penelitian ini adalah air limbah yang diambil dari limbah cuci mobil dan motor. Proses dijalankan secara batch menggunakan alat yang didesain dengan prinsip elektroflokulasi dengan kapasitas maksimum 5 liter. Parameter yang digunakan adalah kandungan Minyak lemak dan Chemical Oxygen Demmand (COD) dengan variasi terhadap Tegangan dan Waktu kontak.

Tahapan yang dilakukan terdiri atas tahap persiapan dan percobaan utama. Pada tahap persiapan, kegiatan yang dilakukan adalah pengambilan sampel dan pengawetan. Pada tahap percobaan utama kegiatan yang dilakukan adalah penentuan tegangan optimum dan penentuan waktu kontak optimum. Variasi tegangan yang digunakan pada saat penentuan tegangan optimum adalah 4,5v; 6v; 7v; 9v dan 12 v. Variasi waktu kontak yang digunakan pada saat penentuan waktu kontak optimum adalah 15 menit, 30 menit, 45 menit, 60 menit, dan 75 menit.

Pada percobaan untuk mengetahui kondisi optimum yang diperlukan bagi proses elektroflokulasi, diperoleh hasil bahwa perubahan yang diberikan terhadap tegangan dan waktu kontak, sangat berpengaruh terhadap perubahan minyak lemak maupun COD.

Downloads

Download data is not yet available.

References

DAFTAR PUSTAKA

Algifari, 2000, Analisis Regresi ; Teori, Kasus, dan Solusi, ed. 2, BPFE, Yogyakarta

Andra, 2008, Tegangan Listrik,

http://elektronik4.blogspot.com, diakses pada 18 Mei 2009.

Chatib, B. 1998. Pengelolaan Air Limbah. ITB. Bandung.

Dimoglo, Anatoly, et al, 2004, Removal of Nickel; Cupper and Mercury from Aqueous Solutions by Electro-Coagulation Using Aluminium Electrodes, Journal of Environmental Engineering Department, Vol 219 No : 4, 29 Sept - 3 Oct 2004.

Faiqun, Ni’am, Moh. 2007. Removal of COD and Turbidity to Improve Waste Water Quality Using Electrocoagulation Technique. Journal of Analytical Sciences. Vol 11 No : 1, 2007 P : 198-205.

Faraday, Michael., 1834, Philosophical Transactions of the Royal Society, www.wikipedia.com, diakses pada 4 Juli 2008.

Khopkar, S.M, 1990, Konsep Dasar Kimia Analitik, halaman, hal 275, UI. Pres, Jakarta.

Manahan, E., Stanley, 1984, Enviromental Chemistry, ed. 7, p : 205-771, Lewis Publisher, New York.

Metcalf, Eddy, 1972, Wastewater Engineering, Metcalf & Eddy. Inc.

Rajkumar, D., 2004, Combined electrochemical degradation and activated carbon adsorption treatments for wastewater containing mixed phenolic compounds, Journal of Environmental Engineering. Vol 10 No :4, 2005 P : 1- 9.

Ramesh, Babu, N.S. Bhadrinarayana, K.M.Meera Sheriffa Begum, Anantharaman N., 2007, Treatment Of Tannery Wastewater By Electrocoagulation, Journal of the University of Chemical Technology and Metallurgy, Vol 42 No: 2, 2007 p: 201-206.

Siregar. Sakti, A., 2005, Instalasi Pengolahan Air Limbah, hal. 15-50, Penerbit Kanisius, Yogyakarta.

Suci. K. Tyas., 2006, Kajian Implementasi Undang-undang Nomor 23 Tahun 1997 tentang Pengelolaan Lingkungan Hidup, http://www.simta.uns.ac.id, diakses pada 19 Desember 2008

Sugiharto, 1987, Dasar – Dasar Pengolahan Air Limbah, Universitas Indonesia, Jakarta.

Supranto, J., 1987, Statistik; Teori dan Aplikasi jilid 1, ed. 5, Penerbit Erlangga, Jakarta.

Sewyer, C.N, 1958, effect of Synthetic Detergent On Sewage Treatment, Journal Sewage and Industrial Waters, University

Wardhana, W.A., 1995, Dampak Pencemaran Lingkungan, ed.1, hal. 82-85, Andi Offset, Yogyakarta.

Downloads

Published

2021-12-15

How to Cite

Suseno, H. P. ., Purnawan, & Kristiyana, S. (2021). Penurunan Konsentrasi Minyak Lemak Dan Cod Pada Limbah Cair Secara Elektroflokulasi. Jurnal Elektrikal, 8(No. 2), 10–16. https://doi.org/10.34151/jurnalelektrikal.v8iNo. 2.3748

Most read articles by the same author(s)

<< < 1 2